# Mechanical, Electrical, and Plumbing Quantity Surveying in Data Center EPC Delivery ## Pages - [Mechanical, Electrical, and Plumbing Quantity Surveying in Data Center EPC Delivery](https://books.osamata.com/data-center-mep-qs/index.llms.md) - [Commercial Governance and EPC Contractual Architecture](https://books.osamata.com/data-center-mep-qs/intro-commercial-architecture.llms.md) - [Volume I: Commercial Governance, Contract Administration, and Pre-Contract Cost Planning](https://books.osamata.com/data-center-mep-qs/volume-1/index.llms.md) - [[[1]{.chapter-number}  [Data Center EPC Delivery Fundamentals]{.chapter-title}]{#sec-epc-delivery-fundamentals .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-1/01-epc-delivery-fundamentals.llms.md) - [[[2]{.chapter-number}  [Equipment Demarcation and Packaging Strategy: OFCI vs. CFCI]{.chapter-title}]{#sec-ofci-vs-cfci .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-1/02-equipment-demarcation-packaging-ofci-vs-cfci.llms.md) - [[[3]{.chapter-number}  [Pre-Contract Cost Planning, Estimating, and Benchmarking]{.chapter-title}]{#sec-cost-planning-benchmarking .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-1/03-pre-contract-cost-planning-estimating-benchmarking.llms.md) - [[[4]{.chapter-number}  [Digital Takeoff, 5D BIM, and Automated Measurement Standards]{.chapter-title}]{#sec-digital-takeoff-5d-bim .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-1/04-digital-takeoff-5d-bim-automated-measurement.llms.md) - [Volume II: Mechanical Infrastructure and Thermal Management Systems Measurement](https://books.osamata.com/data-center-mep-qs/volume-2/index.llms.md) - [[[5]{.chapter-number}  [Central Chilled Water Plants and Primary Heat Rejection]{.chapter-title}]{#sec-central-chilled-water-plants .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-2/05-central-chilled-water-plants-heat-rejection.llms.md) - [[[6]{.chapter-number}  [Air Handling, Containment, and White Space Cooling]{.chapter-title}]{#sec-air-handling-containment .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-2/06-air-handling-containment-white-space-cooling.llms.md) - [[[7]{.chapter-number}  [Liquid Cooling, High-Density Architectures, and Technology Cooling Systems (TCS)]{.chapter-title}]{#sec-liquid-cooling-tcs .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-2/07-liquid-cooling-technology-cooling-systems.llms.md) - [Volume III: Mission-Critical Electrical Infrastructure and Power Systems Measurement](https://books.osamata.com/data-center-mep-qs/volume-3/index.llms.md) - [[[8]{.chapter-number}  [High-Voltage (HV) and Medium-Voltage (MV) Power Distribution]{.chapter-title}]{#sec-hv-mv-power-distribution .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-3/08-hv-mv-power-distribution.llms.md) - [[[9]{.chapter-number}  [Standby Generation and Emergency Power Systems]{.chapter-title}]{#sec-standby-generation-emergency-power .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-3/09-standby-generation-emergency-power.llms.md) - [[[10]{.chapter-number}  [Uninterruptible Power Supply (UPS) and Energy Storage]{.chapter-title}]{#sec-ups-energy-storage .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-3/10-ups-energy-storage.llms.md) - [[[11]{.chapter-number}  [Low-Voltage (LV) Distribution and White Space Power Delivery]{.chapter-title}]{#sec-lv-distribution-white-space-power .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-3/11-lv-distribution-white-space-power-delivery.llms.md) - [[[12]{.chapter-number}  [Earthing, Bonding, and Lightning Protection]{.chapter-title}]{#sec-earthing-bonding-lightning .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-3/12-earthing-bonding-lightning-protection.llms.md) - [Volume IV: Specialized Fire Protection, Mission-Critical Plumbing, and Life Safety](https://books.osamata.com/data-center-mep-qs/volume-4/index.llms.md) - [[[13]{.chapter-number}  [Fire Suppression Systems for Mission-Critical White Space]{.chapter-title}]{#sec-fire-suppression-white-space .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-4/13-fire-suppression-for-white-space.llms.md) - [[[14]{.chapter-number}  [Fire Detection and Very Early Smoke Detection Apparatus (VESDA)]{.chapter-title}]{#sec-fire-detection-vesda .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-4/14-fire-detection-vesda.llms.md) - [[[15]{.chapter-number}  [Mission-Critical Plumbing, Drainage, and Environmental Protection]{.chapter-title}]{#sec-plumbing-drainage-environmental .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-4/15-mission-critical-plumbing-drainage-environmental-protection.llms.md) - [Volume V: Automation, Building Management, and Telecommunication Infrastructure](https://books.osamata.com/data-center-mep-qs/volume-5/index.llms.md) - [[[16]{.chapter-number}  [Extra-Low Voltage (ELV), Security, and Access Control]{.chapter-title}]{#sec-elv-security-access-control .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-5/16-elv-security-access-control.llms.md) - [[[17]{.chapter-number}  [Building Management Systems (BMS), EPMS, and DCIM]{.chapter-title}]{#sec-bms-epms-dcim .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-5/17-bms-epms-dcim.llms.md) - [Volume VI: Procurement Execution, Subcontract Management, and Supply Chain](https://books.osamata.com/data-center-mep-qs/volume-6/index.llms.md) - [[[18]{.chapter-number}  [Vendor Package Management and Procurement Strategy]{.chapter-title}]{#sec-vendor-package-procurement .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-6/18-vendor-package-management-procurement-strategy.llms.md) - [[[19]{.chapter-number}  [Variation Governance, Change Control, and Claims Management]{.chapter-title}]{#sec-variation-governance-claims .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-6/19-variation-governance-change-control-claims.llms.md) - [Volume VII: Testing, Commissioning, Integrated Systems Testing, and Closeout](https://books.osamata.com/data-center-mep-qs/volume-7/index.llms.md) - [[[20]{.chapter-number}  [The Five-Level Commissioning Commercial Framework]{.chapter-title}]{#sec-five-level-commissioning .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-7/20-the-five-level-commissioning-commercial-framework.llms.md) - [[[21]{.chapter-number}  [Temporary Commissioning Infrastructure, Power, and Utilities]{.chapter-title}]{#sec-temporary-commissioning-utilities .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-7/21-temporary-commissioning-infrastructure-power-utilities.llms.md) - [[[22]{.chapter-number}  [Handover, Final Accounts, and Operational Transition]{.chapter-title}]{#sec-handover-final-accounts .quarto-section-identifier}](https://books.osamata.com/data-center-mep-qs/volume-7/22-handover-final-accounts-operational-transition.llms.md) - [References](https://books.osamata.com/data-center-mep-qs/references.llms.md)